Home AI-ArtificialIntelligence Artificial Intelligence Improves Patient Follow-up | OPTH

Artificial Intelligence Improves Patient Follow-up | OPTH

by Hataf Finance
27 minutes read

Introduction

Early detection of diabetic retinopathy (DR) through regular retinal screening is critical to preventing vision loss. However, only around 50% to 60% of all diabetic patients in the United States receive the exam recommended by DR screening guidelines, and fewer than 40% of patients at high risk of vision loss receive appropriate treatment.1–3 The prevalence of DR challenges Wilson and Jungner’s principle that facilities for diagnosis and treatment should be available for screening and follow-up.4 During the past two decades, progress in teleophthalmology-based DR screening, consisting of remote, asynchronous interpretation of fundus photographs by experienced human readers, has offered an avenue to overcome some of these barriers.5–9 More recently, artificial intelligence (AI)-based technologies for DR screening have the potential to further address this challenge by offering expert-level diagnostic ability at a low marginal cost.10–13

The ultimate public health impact of a screening program, though, is determined by whether patients identified as having referrable disease during screening subsequently receive appropriate follow-up care. A variety of barriers may prevent follow-up of a positive DR screening result including a lack of awareness of the result, a lack of understanding about the appropriate next step, and a lack of access to an ophthalmologist. Whereas human-based teleophthalmology systems may return a screening result to the patient in three to five days, AI-based technology can return a result within minutes. This synchrony of the result with the timing of the screening encounter may alleviate some of the barriers to follow-up. Indeed, previous studies have suggested that AI-based screening for DR may increase the rate of adherence to recommended referral services.14,15

To expand access to DR screening, the Stanford Teleophthalmology Automated Testing and Universal Screening (STATUS) program was developed as a collaboration between Byers Eye Institute of Stanford and seven affiliated primary care clinics throughout the San Francisco Bay Area. The first 18 months of the STATUS program involved a store-and-forward teleophthalmology program in which fundus photographs were interpreted asynchronously by remote retina specialists. Subsequently, the FDA-approved autonomous AI screening device for DR, IDx-DR (recently renamed LumineticsCoretm), was integrated into the screening program.10 As detailed in our previous work, an AI–Human Hybrid Workflow was established in which fundus images that were ungradable by the AI system were evaluated in the human-based teleophthalmology workflow.16

In this paper, we present results on patient follow-up across three years of a program for DR screening involving human teleophthalmology and AI. The goals of this study were three-fold. First, we wished to determine the proportion of patients who followed up with an ophthalmologist after a referrable result from their eye screening encounter. Second, we sought to understand the reasons that patients followed up or failed to do so after a referrable screening result. Finally, we wanted to determine if the proportion of patients who followed up was positively or negatively impacted by the AI screening system compared to a human-based teleophthalmology system. We hypothesized that the AI system would increase the rate of patient follow-up after a positive screening result.

Methods

Program Overview

The Stanford Teleophthalmology Automated Testing and Universal Screening (STATUS) program is a DR screening program that was initiated between the Byers Eye Institute at Stanford University, five Stanford-affiliated regional primary care sites (Santa Clara, Los Gatos, Hayward, Castro Valley, and Pleasanton), and two Stanford-affiliated endocrinology clinics (Palo Alto, Emeryville) in the San Francisco Bay Area in September 2019. For the first 18 months of the program, screening was performed through store-and-forward human-based teleophthalmology workflow (“Human Workflow”). Subsequently, patient screening was performed with the IDx-DR (Digital Diagnostics Inc., Coralville, IA; recently renamed LumineticsCoretm), an autonomous AI-based medical device approved for the evaluation of DR in primary care offices (“AI Workflow”). During this phase of the program, fundus images that received an ungradable result from the AI system were evaluated by the human-based teleophthalmology workflow (“AI–Human Hybrid Workflow”).

Regardless of workflow, all patients received their results via a health system-based web portal where patients can view test results, access their medical records, and conduct other health-related activities. Patients were alerted to the new result by email or text message. Aside from AI- or human-based DR screening and an automated notification of results sent via the patient’s web-based health portal, the STATUS program did not otherwise alter patient notification and referral placement processes already established at participating sites. In general, activities at the sites included clinic staff members notifying patients of their results by phone, text message, or email and notifying them of a referral to ophthalmology, if indicated. Specifically, any patient with more-than-mild-DR (MTMDR) or an ungradable AI–Human Hybrid Workflow screening result was called regarding their result, and in these cases the primary care physician (PCP) placed a referral to ophthalmology for in-person examination. Patients were not assumed to have an established ophthalmologist and had the option to choose any qualified ophthalmologist depending on insurance coverage, scheduling availability, location, and other matters of patient preference. After the referral was placed, patients either contacted their ophthalmologist of choice or were contacted by the accepting ophthalmologists’ office to schedule an in-person appointment. Consequently, the only prescribed difference between the Human Workflow, the AI Workflow, and the AI–Human Hybrid Workflow was the difference in time to notification of screening result due to varying image interpretation methods. In the Human Workflow and the AI–Human Hybrid Workflow, results were released one to five days after the screening encounter when the retinal specialist had completed the remote image evaluation; the referral process described above began thereafter. In the AI Workflow, the patient received the health portal result within 12 hours and often the screening result was delivered at the point of care within minutes.

Patient Evaluation and Image Interpretation

Patients 18 years or older with type 1 or type 2 diabetes mellitus without a prior DR diagnosis or a DR exam in the past 12 months being seen at one of the affiliated STATUS program clinics (see Program Overview) were offered the opportunity to have DR screening performed during their primary care visit.

During the initial phase of the program under the Human Workflow, one 45-degree macula-centered image and one optic disc-centered image for each eye were obtained with a non-mydriatic fundus camera (TopCon NW400, Welch Allyn Inc., Skaneateles Falls, NY) in the absence of pharmacologic pupil dilation and saved to Picture Archiving and Communication Software (PACS). A rotating pool of fellowship-trained retina specialists at the Stanford Ophthalmic Reading Center (STARC) performed single-reader evaluation using the International Clinical Diabetic Retinopathy Severity Scale to determine the stage of DR (no DR, mild non-proliferative diabetic retinopathy (NPDR), moderate NPDR, severe NPDR, proliferative DR) and the presence or absence of diabetic macular edema (DME).17 Readers could also label the fundus images as ungradable if the quality was not sufficient to diagnose DR or DME. Image interpretation was performed on the native PACS software that allowed readers to manipulate image brightness and contrast (Zeiss Forum, Carl Zeiss Meditec, Dublin, CA). In this human-based teleophthalmology workflow, the time of screening to release of results took one to five days. During the AI Workflow, image acquisition was identical through the same TopCon NW400 camera system; the only difference was that image interpretation was performed by the IDx-DR through a secure cloud-based algorithm. Within five minutes, the device’s software displayed a screening result of MTMDR-positive, MTMDR-negative, or ungradable. Patients were informed of their test result as described above.

Data Collection and Analysis

For all patients screened in the STATUS program who received a MTMDR-positive or ungradable result during the Human Workflow, AI Workflow, or AI–Human Hybrid Workflow, the electronic medical record at Stanford Health Care was searched for subsequent encounters with an ophthalmologist. The data were cleaned and scraped using Pandas. The patient was considered to have successful follow-up if the in-person encounter with dilated fundus examination took place within 90 days of the screening encounter.

To test the hypothesis that sooner release of screening result under the AI Workflow would improve follow-up rates, we compared the rates of follow-up between the human-teleophthalmology phase (“Human Workflow”) and the AI screening phase (“AI Workflow”). Additionally, to account for any cohort differences between the two phases, as well as other effects introduced by the AI system apart from a more rapid result, we also looked at the rate of follow-up for patients who received an initial inconclusive screening result from the AI system that was then read as MTMDR in the human-teleophthalmology workflow 1–5 days later as described above (“AI–Human Hybrid Workflow”). Comparison was performed between rates of follow-up at the university health system since documentation of follow-up in the community was not available across all conditions. The chi-square test of independence was used to compare rates between these groups.

Patients who received a diagnosis of MTMDR-positive in the AI Workflow were randomly sampled and contacted by phone for a survey regarding follow-up behavior (Supplementary Material 1). Among 152 patients who were sampled and called, 93 (63.4%) were reached by phone, and all 93 provided consent to participate in the survey. Patient follow-up outside Stanford Health Care was calculated based on the self-reported behavior of the sample of 93 survey respondents. Of 93 patients who provided consent for the phone survey, 68 had followed up with an ophthalmologist, whereas 25 had not.

Approval for this study was obtained from the Stanford University Institutional Review Board in Protocol #57104. All guidelines outlined in the Declaration of Helsinki were followed, and informed consent was obtained from study participants.

Results

Under the AI Workflow, the program screened 2243 patients during the study period and identified 279 of them as positive for MTMDR. Among these 279 patients who received a screening result of MTMDR from the AI system, 69.2% followed up with an ophthalmologist within 90 days of the screening encounter, including 35.5% of patients who presented to the university eye center and 33.7% who presented to a community eye doctor (Figure 1; Supplementary Table 1). Among the patients who followed up at the university eye institute, 9.1% received treatment for diabetic eye disease at the first follow-up encounter (N=8 intravitreal anti-VEGF injection; N=1 pan-retinal photocoagulation). The screening program served racially and ethnically diverse populations (Asian 33.1%, White Non-Hispanic/Latino 25.0%, Hispanic/Latino 21.2%, Black 7.4%, Native American/Pacific Islander 2.5%, Other/Unknown 10.8%), with four self-reported demographic racial or ethnic groups representing a plurality at different clinic sites (Figure 2).

Figure 1 A flowchart representing patients involved in the study. “Human Workflow” indicates a store-and-forward human-based teleophthalmology system in which fundus images were interpreted by a retina specialist one to five days after acquisition. “AI Workflow” indicates assessment by the AI system without human teleophthalmology involvement. “AI–Human Hybrid Workflow” indicates fundus images that received an ungradable result from the AI system and were subsequently evaluated by the human-based teleophthalmology system, producing a result in one to five days.

Figure 2 Pie graphs representing the racial and ethnic composition served at the seven clinic sites in the diabetic retinopathy screening program.

To further understand patients’ follow-up behavior, we conducted a survey by phone of patients with a MTMDR-positive screening result from the AI system. Of 93 patients who provided consent for the phone survey, 68 had followed up with an ophthalmologist, whereas 25 had not. For patients who followed up with an ophthalmologist after a referrable screening result, the most frequent reason was that “I was referred by my PCP”, which was given 70.5% of the time (N=48/68). Other reasons included that the location had been recommended as reputable and that it was in their insurance network (Figure 3A). Patients who did not follow-up after a MTMDR diagnosis most commonly gave the reason that they were not aware that they were supposed to follow-up (despite receiving an electronic message through MyHealth about the referral and need for follow-up), which was stated 52% of the time (N=13/25). Other reasons for failure to follow up included a language barrier or difficulty with translation, issues with scheduling, feeling that follow-up was not a priority in their lives at that time, and having fear of an unwanted diagnosis (Figure 3B). For patients who did not follow up after their encounter, 76.0% (N=19/25) of respondents said that they did not have an established eye doctor. A variety of other demographic and health factors showed no statistically significant difference between the patients who followed up or did not follow up including gender, age, glucose levels, body-mass index, or smoking status (Supplementary Tables 2 and 3). We also investigated differences in socioeconomic status proxies such as zip code and home value estimates and found no statistically significant difference between groups.

Figure 3 (A) Patients’ responses regarding the reasons that they chose their follow-up site with an ophthalmologist following a MTMDR diagnosis. (B) Patients’ responses regarding the reasons that they failed to follow-up with an ophthalmologist following a MTMDR diagnosis.

Under the Human Workflow, 12.0% of patients with a screening result warranting referral to an ophthalmologist followed up for an eye exam (Referrable, N=14/117; MTMDR-positive result, N=8/40; ungradable result, N=6/77). In comparison, after a MTMDR-positive result in the AI Workflow 35.5% of patients followed up for an eye exam at the university eye institute (N=99/279). Finally, for patients under the AI–Human Hybrid Workflow, 11.7% of patients followed up at the university eye institute (Referrable, N=12/103; MTMDR-positive result, N=1/20; ungradable result, N=11/83) (Figure 1). This represented a three-fold increase in follow-up with an ophthalmologist under the AI Workflow compared to either the Human Workflow or AI–Human Hybrid Workflow (AI vs Human vs AI–Human Hybrid χ2df=2 = 36.70, p < 0.00000001; AI vs Human Workflow χ2df=1 = 21.22, p < 0.000004; AI vs AI–Human Hybrid χ2df=1 = 19.59, p < 0.00001; Human vs AI–Human Hybrid χ2df=1 = 0, p = 1).

Discussion

As rates of diabetes mellitus steadily increase both in the US and around the world, a public health crisis of DR looms. AI-based diabetic eye screening may help to meet the rising volume of patients. However, the number of patients screened is only an initial target in mitigating DR; the ultimate goal of DR screening is for patients identified as positive for MTMDR to receive the necessary subspeciality-specific monitoring and treatment. To this end, although teleophthalmology programs have expanded access to screening, many patients who screen positive do not follow up for eye care after referral.18 Whereas human-based teleophthalmology workflows typically have a delay between screening encounter and receipt of screening result, AI algorithms can return a result at the point of care. This study assessed differences in follow-up rate between AI and Human Workflows. The only prescribed difference between AI and Human Workflow was the method of image analysis, which altered time to result (0–12 hours for AI Workflow, 1–5 days for Human Workflow) but was unknown to the patient. There were no baseline differences between study populations. Hence, we inferred that the differences in follow-up rate may have been driven by differences in time that result was released to the patient. Further comparison with the AI–Human Hybrid Workflow, which also took 1–5 days and would isolate other differences such as the Hawthorne Effect of the AI Workflow, found a similar follow-up rate between the AI–Human Hybrid and the Human Workflow. Overall, DR screening under the AI Workflow with shorter time to result had a three-fold increase in follow-up with an ophthalmologist compared to the workflows involving human intervention.

This work has several strengths that complement previous studies. First, the study takes place in an ethnically and racially diverse United States population. Whereas previous studies have investigated referral behavior in a Rwandan population or a predominantly African American population, our cohort is composed of large numbers of self-reported Asian, Hispanic and Latino, Black, White non-Hispanic/Latino, and Native American or Pacific Islander patients.14,15 We further investigated differences between demographics and socioeconomic status proxies such as zip code and home value estimates and found no difference to suggest that differences in follow-up rates were driven by demographic or socioeconomic status (Supplementary Tables 2 and 3). Second, our study was conducted with patients screened with IDx-DR, the first approved AI-based medical device for DR evaluation. We compared rates of follow-up in the AI Workflow, which screened with IDx-DR, to two comparison groups: a human-based teleophthalmology workflow (“Human Workflow”) and an AI–Human Hybrid Workflow. The comparison to the AI–Human Hybrid Workflow is important to minimize confounding effects that could be present by only comparing to a historical cohort. Moreover, our analysis of patients who were initially tested by AI and then screened by a human provider served as a control for changes attributed to patient behavior factors other than those related to the time interval to an image interpretation. The study reports both relative rate of follow-up as well as an overall estimate of follow-up after AI screening. Finally, our analysis of follow-up rates is complemented by survey results by the patients themselves that support the principle of why an AI system may enhance referral compliance.

Patients who failed to follow up with an ophthalmologist most often reported that they were unaware of the positive screening result or the next step in management, despite being sent a secure electronic message from their provider about the result and that a referral was placed. Although clinic staff ensured that each patient was contacted with their screening result and had a referral to ophthalmology placed, a variety of communication, educational, and/or technological barriers may have stood in the way. Patients also reported language barriers to scheduling follow-up, that addressing the diagnosis was a low priority, and being fearful of an unwanted diagnosis of DR. These barriers could potentially be addressed through clinic workflow changes. For language barriers specifically, our health system lists patients’ preferred language, and schedulers are asked to contact patients in their preferred language using phone-based interpreter services. However, it is unknown whether these services are available in all community ophthalmology clinics which served patients in the study. Opportunities for improvement in follow-up include an automated process for generating referrals in the patient’s native language. Similarly, the top reason for selecting the location of follow-up among patients who did follow up after a positive screening result was that they were referred by their primary care doctor, highlighting the importance of the primary care encounter in directing health behaviors.

The study has several limitations. First, the descriptive and retrospective analyses leave open the potential for bias not addressed by randomization. Nevertheless, the results establish a foundation for future randomized controlled trials, particularly in a US population to complement previous international studies.14 A second limitation is that the overall rate of follow-up in this study was calculated from a sample of MTMDR patients. Patients who were not included in the sample or who did not answer the phone may have differed from those from whom the survey results were collected. Eliciting responses from a greater proportion of patients would strengthen the conclusions drawn from the data. Nevertheless, the survey results would not affect the relative rates of follow-up calculated between the AI Workflow and other workflows. Finally, while surveyed patients did not directly report that the time to screening result impacted their follow-up behavior, they may have been anchored by the provided list of response options or may not have consciously recognized the impact of a delayed result on their own health care decision-making. To adhere to best practices for conducting surveys, phone calls were performed with a standardized script (Supplementary Material 1), which in this case provided a set of responses to which patients could agree or disagree before providing original responses. The survey in this study was conducted over a year after patients in the Human Workflow had been screened, so patient recall of behavior and reasoning was likely not sufficient for explicit qualitative investigation of relationship between time to result and choice of follow-up. However, such questions could be explored in future studies, and there is reason to believe that the qualitative responses provided in the surveys here still give insight into the general factors that influenced patients’ health care decision-making.

In conclusion, this study reports that more than two-thirds of patients who received a positive result for MTMDR by the AI Workflow followed up with an ophthalmologist within 90 days. The rate of follow-up at the university eye clinic was three times greater in the AI Workflow compared to patients who received their screening result up to 1 week later under a human-based teleophthalmology workflow or AI–Human Hybrid Workflow. Survey results suggested several factors influencing patient follow-up behavior that may be addressed through modifications in post-visit messaging at or soon after the point of care between the patient and their provider, including clear communication of results, emphasis on the importance of ophthalmology follow-up, availability of results and further instructions in multiple languages, and counseling that treatment options may be available if follow-up is completed in a timely manner. The research was conducted in a diverse United States population across multiple primary care clinics using an FDA-approved medical device. In addition to expanding access to DR screening and lowering costs, AI-based devices may also improve eye care by synchronizing testing results with the patient-provider encounter.

Funding

Theodore Leng: Institutional grants from Research to Prevent Blindness, NIH grant P30-EY026877, Astellas. Consulting fees from Roche/Genentech, Protagonist Therapeutics, Alcon, Regeneron, Graybug, Boehringer Ingelheim, Kanaph. Participation in Data Safety Monitoring or Advisory Board for Nanoscope Therapeutics, Apellis, Astellas. Diana Do: Grants from Regeneron, Kriya, Boerhinger Ingelheim. Consulting fees from Genentech, Regeneron, Kodiak Sciences, Apellis, Iveric Bio. David Myung: Institutional grants from Research to Prevent Blindness, NIH grant P30-EY026877, Stanford Diabetes Research Center (SDRC).

Disclosure

This research was funded in part by the Research to Prevent Blindness and NIH grant P30-EY026877, as well as the Stanford Diabetes Research Center (SDRC). Authors with financial interests or relationships to disclose are listed after the references. Dr Diana V Do reports grants, personal fees from Regeneron, personal fees from Apellis, personal fees from Kodiak Sciences, personal fees from Iveric Bio, during the conduct of the study. Dr Vinit B Mahajan reports other from DIigital Diagnostics, LLC, during the conduct of the study; Dr Theodore Leng reports grants, personal fees from Astellas, personal fees from Roche/Genentech, personal fees from Protagonist, personal fees from Nanoscope, personal fees from Alcon, personal fees from Apellis, personal fees from Regeneron, personal fees from Graybug, personal fees from Kanaph, personal fees from Boehringer Ingelheim, outside the submitted work. None of the remaining authors have any conflicts of interest to disclose.

References

1. Elham Hatef MD, Bruce G, Vanderver MD, Peter Fagan P, Michael Albert MD, Miriam Alexander MD. Annual diabetic eye examinations in a managed care Medicaid population. Am J Manag Care. 2015;21(5):e297–e302.

2. Hazin R, Barazi MK, Summerfield M. Challenges to establishing nationwide diabetic retinopathy screening programs. Curr Opin Ophthalmol. 2011;22(3):174–179. doi:10.1097/ICU.0b013e32834595e8

3. Eppley SE, Mansberger SL, Ramanathan S, Lowry EA. Characteristics associated with adherence to annual dilated eye examinations among US patients with diagnosed diabetes. Ophthalmology. 2019;126(11):1492–1499. doi:10.1016/j.ophtha.2019.05.033

4. Wilson JMG, Jungner G. Principles and Practice of Screening for Disease. World Health Organization; 1968.

5. Davis RM, Fowler S, Bellis K, Pockl J, Pakalnis V, Woldorf A. Telemedicine improves eye examination rates in individuals with diabetes: a model for eye-care delivery in underserved communities. Diabetes Care. 2003;26(8):2476–2477. doi:10.2337/diacare.26.8.2476

6. Conlin PR, Fisch BM, Cavallerano AA, Cavallerano JD, Bursell SE, Aiello LM. Nonmydriatic teleretinal imaging improves adherence to annual eye examinations in patients with diabetes. J Rehabil Res Dev. 2006;43(6):733–740. doi:10.1682/JRRD.2005.07.0117

7. Whitestone N, Nkurikiye J, Patnaik JL, et al. Feasibility and acceptance of artificial intelligence-based diabetic retinopathy screening in Rwanda. Br J Ophthalmol. 2023:bjo-2022–322683. doi:10.1136/bjo-2022-322683

8. Cleland CR, Rwiza J, Evans JR, et al. Artificial intelligence for diabetic retinopathy in low-income and middle-income countries: a scoping review. BMJ Open Diabetes Res Care. 2023;11(4):e003424. doi:10.1136/bmjdrc-2023-003424

9. Noriega A, Meizner D, Camacho D, et al. Screening diabetic retinopathy using an automated retinal image analysis system in independent and assistive use cases in Mexico: randomized controlled trial. JMIR Form Res. 2021;5(8):e25290. doi:10.2196/25290

10. Abràmoff MD, Lavin PT, Birch M, Shah N, Folk JC. Pivotal trial of an autonomous AI-based diagnostic system for detection of diabetic retinopathy in primary care offices. Npj Digital Med. 2018;1(1):1–8. doi:10.1038/s41746-018-0040-6

11. Bhaskaranand M, Ramachandra C, Bhat S, et al. The value of automated diabetic retinopathy screening with the EyeArt system: a study of more than 100,000 consecutive encounters from people with diabetes. Diabetes Technol Ther. 2019;21(11):635–643. doi:10.1089/dia.2019.0164

12. Ipp E, Liljenquist D, Bode B, et al. Pivotal evaluation of an artificial intelligence system for autonomous detection of referrable and vision-threatening diabetic retinopathy. JAMA Network Open. 2021;4(11):e2134254. doi:10.1001/jamanetworkopen.2021.34254

13. Natarajan S, Jain A, Krishnan R, Rogye A, Sivaprasad S. Diagnostic accuracy of community-based diabetic retinopathy screening with an offline artificial intelligence system on a smartphone. JAMA Ophthalmol. 2019;137(10):1182–1188. doi:10.1001/jamaophthalmol.2019.2923

14. Mathenge W, Whitestone N, Nkurikiye J, et al. Impact of artificial intelligence assessment of diabetic retinopathy on referral service uptake in a low-resource setting: the RAIDERS randomized trial. Ophthalmol Sci. 2022;2(4):100168. doi:10.1016/j.xops.2022.100168

15. Liu J, Gibson E, Ramchal S, et al. Diabetic retinopathy screening with automated retinal image analysis in a primary care setting improves adherence to ophthalmic care. Ophthalmol Retina. 2021;5(1):71–77. doi:10.1016/j.oret.2020.06.016

16. Dow ER, Khan NC, Chen KM, et al. AI-Human Hybrid Workflow enhances teleophthalmology for the detection of diabetic retinopathy. Ophthalmol Sci. 2023;3(4):100330. doi:10.1016/j.xops.2023.100330

17. Wilkinson CP, Ferris FL, Klein RE, et al. Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales. Ophthalmology. 2003;110(9):1677–1682. doi:10.1016/S0161-6420(03)00475-5

18. Pernic A, Kaehr MM, Doerr ED, Koczman JJ, Yung CWR, Phan ADT. Analysis of compliance with recommended follow-up for diabetic retinopathy in a county hospital population. Invest Ophthalmol Vis Sci. 2014;55(13):2290.

Source link

You may also like

Leave a Comment

Hataf News Unleash the Power of Financial Insight! Stay ahead of the game with our dynamic platform, delivering real-time updates, expert analysis, and exclusive market trends. Empower your financial decisions with Hataf News and make your wealth thrive!

Hataf News, A Media Company – All Right Reserved. Designed and Developed by Hataf Tech

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept Read More